{"product_id":"aerial-ad-40","title":"Dehumidifier Aerial AD 40 Dantherm Group","description":"\u003ch2\u003eDehumidifier Aerial AD 40 Dantherm Group\u003c\/h2\u003e\n\u003ch3\u003eWhat it is\u003c\/h3\u003e\n\u003cp\u003eDehumidifier Aerial AD 40 Dantherm Group. Key specifications: working humidity range % RH, capacity, 30 °C\/80% RH, energy consumption 33,5\/615 l\/24h\/W, capacity, 20 °C\/60% RH, energy consumption 16\/470 l\/24h\/W.\u003c\/p\u003e\n\u003cp\u003eDehumidifiers and heat pumps are units that extract moisture from the air to dry rooms, building sites and indoor swimming pools, or heat pool water.\u003c\/p\u003e\n\u003ch3\u003eWhat it is for\u003c\/h3\u003e\n\u003cp\u003eUsed for air conditioning indoor spaces, for dehumidifying rooms and structures and for dehumidifying indoor spaces.\u003c\/p\u003e\n\u003ch3\u003eHow to use it\u003c\/h3\u003e\n\u003cp\u003eStand the unit level, away from walls to allow air to circulate, and close the doors and windows of the room being treated. Set the desired humidity level or temperature and drain the condensate into the tank or through a hose to a drain. Clean the air filter regularly; install and connect fixed units and heat pumps as described in the manual.\u003c\/p\u003e\n\u003ch3\u003eWhere it is used\u003c\/h3\u003e\n\u003cul\u003e\u003cli\u003eBuilding services\u003c\/li\u003e\u003cli\u003eBuilding maintenance\u003c\/li\u003e\u003cli\u003eRenovation\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eWorking humidity range:\u003c\/strong\u003e % RH\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eCapacity, 30 °C\/80% RH, energy consumption:\u003c\/strong\u003e 33,5\/615 l\/24h\/W\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eCapacity, 20 °C\/60% RH, energy consumption:\u003c\/strong\u003e 16\/470 l\/24h\/W\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eCapacity, 15 °C\/60% RH, energy consumption:\u003c\/strong\u003e 13\/410 l\/24h\/W\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eAir flow, speed III (m³\/h):\u003c\/strong\u003e 300\/400\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eWorking temperature range:\u003c\/strong\u003e 5-34 °C\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eMaximum power draw (W):\u003c\/strong\u003e 800\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eTank capacity (L):\u003c\/strong\u003e 6,8\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eCondensate drain hose:\u003c\/strong\u003e 15 x 2 mm\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eCable length:\u003c\/strong\u003e 4.5 with male plug\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eProtection class:\u003c\/strong\u003e IPX4\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eWho it is for\u003c\/h3\u003e\n\u003cp\u003eDesigned for industrial maintenance technicians and HVAC technicians.\u003c\/p\u003e\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity (30 °C\/80% RH)\/power consumption\u003c\/td\u003e\n\u003ctd\u003el\/24h\/W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity (20 °C\/60% RH)\/power consumption\u003c\/td\u003e\n\u003ctd\u003el\/24h\/W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity (15 °C\/60% RH)\/power consumption\u003c\/td\u003e\n\u003ctd\u003el\/24h\/W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir flow (speed I\/II)\u003c\/td\u003e\n\u003ctd\u003em³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature range\u003c\/td\u003e\n\u003ctd\u003e°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity range\u003c\/td\u003e\n\u003ctd\u003e% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003eV\/Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise level\u003c\/td\u003e\n\u003ctd\u003edB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTank capacity\u003c\/td\u003e\n\u003ctd\u003el\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003etype\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower cable\u003c\/td\u003e\n\u003ctd\u003em\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct dimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003emm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003ekg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRelated products\u003c\/h3\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"\/en\/products\/aerial-ad-520\"\u003eDehumidifier Aerial AD 520 Dantherm Group\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"\/en\/products\/aerial-ad-20\"\u003eDehumidifier Aerial AD 20 Dantherm Group\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"\/en\/products\/master-anello-adattatore-o508-mm-per-riscaldatori-daria-elettrici-rs-40-dantherm-group\"\u003eAdapter Ring - Ø508mm for RS 40 Electric Air Heaters, Master, Dantherm Group\u003c\/a\u003e \u0026mdash; from the category \u003ca href=\"\/en\/collections\/generatori-daria-calda-elettrici-e-a-gas\"\u003eElectric and Gas Hot Air Heaters\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"\/en\/products\/firma-fp-56\"\u003eDichloroisocyanurate for water chlorination FP 56 Firma Chimica\u003c\/a\u003e \u0026mdash; from the category \u003ca href=\"\/en\/collections\/piscine-e-accessori\"\u003eSwimming Pools and Accessories\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"\/en\/products\/master-prolunga-32a-10-m-per-riscaldatori-b-15-b-18-b-22-heylo-ew-18-e-dantherm-group\"\u003eExtension cable 32 A \/ 10 m for heaters B 15, B 18, B 22, Heylo EW 18-e Master Dantherm Group\u003c\/a\u003e \u0026mdash; from the category \u003ca href=\"\/en\/collections\/spine-e-prese-uso-industriale-e-da-cantiere-heavy-duty-ip44-iec-60309-certificate-stagne-alta-protezione-ip67\"\u003eSite Electrical Equipment: Plugs, Sockets, Cables and Extension Leads\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003eBrowse the whole category: \u003ca href=\"\/en\/collections\/deumidificatori-e-pompe-di-calore\"\u003eDehumidifiers and Heat Pumps\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eBefore you order\u003c\/h3\u003e\n\u003cp\u003eIn your request, please state the length and the quantities required, so we can give you the right quotation first time.\u003c\/p\u003e\n\u003cp\u003eFor prices and availability, \u003cstrong\u003erequest a quote from AMES Srl\u003c\/strong\u003e: we will reply with our quotation, delivery times and, where needed, an equivalent technical alternative.\u003c\/p\u003e","brand":"Dantherm Group","offers":[{"title":"Standard","offer_id":57763004875084,"sku":"aerial-ad-40","price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/9864\/0716\/files\/Aerial-AD-40.jpg?v=1781107619","url":"https:\/\/www.amessrl.it\/en\/products\/aerial-ad-40","provider":"A.M.E.S. srl","version":"1.0","type":"link"}