{"product_id":"calorex-dh-15","title":"Dehumidifier Calorex DH 15 Dantherm Group","description":"\u003ch2\u003eDehumidifier Calorex DH 15 Dantherm Group\u003c\/h2\u003e\n\u003ch3\u003eWhat it is\u003c\/h3\u003e\n\u003cp\u003eDehumidifier Calorex DH 15 Dantherm Group. Key specifications: working temperature range 0-35 °C, dehumidifying capacity at 20 °C\/60% RH 11,0 l\/24h, specific energy consumption (SEC) at 20°C\/60°C RH 0.62 kWh\/l.\u003c\/p\u003e\n\u003cp\u003eDehumidifiers and heat pumps are units that extract moisture from the air to dry rooms, building sites and indoor swimming pools, or heat pool water.\u003c\/p\u003e\n\u003ch3\u003eWhat it is for\u003c\/h3\u003e\n\u003cp\u003eUsed for air conditioning indoor spaces, for dehumidifying rooms and structures and for dehumidifying indoor spaces.\u003c\/p\u003e\n\u003ch3\u003eHow to use it\u003c\/h3\u003e\n\u003cp\u003eStand the unit level, away from walls to allow air to circulate, and close the doors and windows of the room being treated. Set the desired humidity level or temperature and drain the condensate into the tank or through a hose to a drain. Clean the air filter regularly; install and connect fixed units and heat pumps as described in the manual.\u003c\/p\u003e\n\u003ch3\u003eWhere it is used\u003c\/h3\u003e\n\u003cul\u003e\u003cli\u003eBuilding services\u003c\/li\u003e\u003cli\u003eBuilding maintenance\u003c\/li\u003e\u003cli\u003eRenovation\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eWorking temperature range:\u003c\/strong\u003e 0-35 °C\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eDehumidifying capacity at 20 °C\/60% RH:\u003c\/strong\u003e 11,0 l\/24h\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eSpecific energy consumption (SEC) at 20°C\/60°C RH:\u003c\/strong\u003e 0.62 kWh\/l\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eWeight of R407C gas, CO2 equivalent:\u003c\/strong\u003e 0,34\/0,6 kg\/t\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eRated absorbed power at 20°C 60% RH (kW):\u003c\/strong\u003e 0,30\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eMaximum FLA (A):\u003c\/strong\u003e 3,8\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eMaximum supply fuse (A):\u003c\/strong\u003e 10\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eStarting inrush current LRA (A):\u003c\/strong\u003e 18\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eHeat recovered at 20 °C\/60% RH (kW):\u003c\/strong\u003e 0,8\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eWho it is for\u003c\/h3\u003e\n\u003cp\u003eDesigned for industrial maintenance technicians and HVAC technicians.\u003c\/p\u003e\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating range – temperature\u003c\/td\u003e\n\u003ctd\u003e°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating range – humidity\u003c\/td\u003e\n\u003ctd\u003e% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDehumidification capacity at 20 °C\/60% RH\u003c\/td\u003e\n\u003ctd\u003el\/24h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecific energy consumption (SEC) at 20 °C\/60% RH\u003c\/td\u003e\n\u003ctd\u003ekWh\/l\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound pressure level at 3 m\u003c\/td\u003e\n\u003ctd\u003edB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eR407C gas weight\/CO₂ equivalent\u003c\/td\u003e\n\u003ctd\u003ekg\/t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003eV\/Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power input at 20 °C\/60% RH\u003c\/td\u003e\n\u003ctd\u003ekW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum FLA current\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush current (LRA)\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct dimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003emm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003ekg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondensate drain size, ID\u003c\/td\u003e\n\u003ctd\u003emm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRelated products\u003c\/h3\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"\/en\/products\/calorex-dh-150\"\u003eDehumidifier Calorex DH 150 Dantherm Group\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"\/en\/products\/aerial-wt-230-240-250-280\"\u003eDehumidifier Aerial WT 230-240-250-280 Dantherm Group\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"\/en\/products\/heylo-tubo-dellaria-per-alte-temperature-o305-mm-per-il-riscaldatore-heylo-de-20-sh-dantherm-group\"\u003eHigh-temperature air duct Ø305 mm for heater Heylo DE 20 SH Dantherm Group\u003c\/a\u003e \u0026mdash; from the category \u003ca href=\"\/en\/collections\/generatori-daria-calda-elettrici-e-a-gas\"\u003eElectric and Gas Hot Air Heaters\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"\/en\/products\/firma-fp-crystal\"\u003eMulti-purpose pool concentrate FP Crystal Firma Chimica\u003c\/a\u003e \u0026mdash; from the category \u003ca href=\"\/en\/collections\/piscine-e-accessori\"\u003eSwimming Pools and Accessories\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"\/en\/products\/master-prolunga-32-a-5-m-per-riscaldatori-b-15-b-18-b-22-dantherm-group\"\u003eExtension lead – 32 A \/ 5 m for Master B 15, B 18, B 22 heaters, Dantherm Group\u003c\/a\u003e \u0026mdash; from the category \u003ca href=\"\/en\/collections\/spine-e-prese-uso-industriale-e-da-cantiere-heavy-duty-ip44-iec-60309-certificate-stagne-alta-protezione-ip67\"\u003eSite Electrical Equipment: Plugs, Sockets, Cables and Extension Leads\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003eBrowse the whole category: \u003ca href=\"\/en\/collections\/deumidificatori-e-pompe-di-calore\"\u003eDehumidifiers and Heat Pumps\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eBefore you order\u003c\/h3\u003e\n\u003cp\u003eIn your request, please state the power rating and the quantities required, so we can give you the right quotation first time.\u003c\/p\u003e\n\u003cp\u003eFor prices and availability, \u003cstrong\u003erequest a quote from AMES Srl\u003c\/strong\u003e: we will reply with our quotation, delivery times and, where needed, an equivalent technical alternative.\u003c\/p\u003e","brand":"Dantherm Group","offers":[{"title":"Standard","offer_id":57763007201612,"sku":"calorex-dh-15","price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/9864\/0716\/files\/Calorex-DH-15-Fire-Station.jpg?v=1783591182","url":"https:\/\/www.amessrl.it\/en\/products\/calorex-dh-15","provider":"A.M.E.S. srl","version":"1.0","type":"link"}