{"product_id":"dantherm-hch-8","title":"Ventilation system Dantherm Hch 8","description":"\u003ch2\u003eVentilation system Dantherm Hch 8\u003c\/h2\u003e\n\u003ch3\u003eWhat it is\u003c\/h3\u003e\n\u003cp\u003eVentilation system Dantherm Hch 8. Key specifications: maximum air flow (m³\/h) 500, max rated flow at 100 Pa 500 Vmax.rated | m³\/h, recommended field of use 80 - 500 V | m³\/h.\u003c\/p\u003e\n\u003cp\u003eThese are air treatment units and components: fans, air purifiers, sanitising systems, heat pumps, ducting, grilles and ventilation fittings.\u003c\/p\u003e\n\u003ch3\u003eWhat it is for\u003c\/h3\u003e\n\u003cp\u003eUsed in air conditioning and air handling systems and for ventilating workplaces.\u003c\/p\u003e\n\u003ch3\u003eHow to use it\u003c\/h3\u003e\n\u003cp\u003eChoose the unit according to the room volume and place it on a stable base, with unobstructed air inlets and ducts as short and straight as possible. Use ozone generators only in rooms with no people or animals present, ventilating before re-entering. Clean or replace filters and grilles periodically.\u003c\/p\u003e\n\u003ch3\u003eWhere it is used\u003c\/h3\u003e\n\u003cul\u003e\u003cli\u003eResidential construction\u003c\/li\u003e\u003cli\u003eBuilding services\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eMaximum air flow (m³\/h):\u003c\/strong\u003e 500\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eMax rated flow at 100 Pa:\u003c\/strong\u003e 500 Vmax.rated | m³\/h\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eRecommended field of use:\u003c\/strong\u003e 80 - 500 V | m³\/h\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eEN 131417 reference flow at 50pa:\u003c\/strong\u003e 350 VREF \/ m³\/h\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eThermal efficiency:\u003c\/strong\u003e Up to 92%\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eBypass:\u003c\/strong\u003e Sì\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eFilters according to EN 779:\u003c\/strong\u003e G4 (optional on supply: F7)\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eSurrounding temperature where the unit is installed:\u003c\/strong\u003e -12 to +50 °C\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eOperational temperature range without preheat:\u003c\/strong\u003e -13 to +50 °C\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eInternal and external leakage to EN:\u003c\/strong\u003e \u0026lt;2% (Class A1) Class\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eDimensions w x h x d:\u003c\/strong\u003e 1180 x 600 x 780 mm\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eDuct connection (mm):\u003c\/strong\u003e 250\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eWeight unit (kg):\u003c\/strong\u003e 70\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eWeight including (kg):\u003c\/strong\u003e 84\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eWho it is for\u003c\/h3\u003e\n\u003cp\u003eDesigned for HVAC technicians and heating and plumbing engineers.\u003c\/p\u003e\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurrounding temperature where the unit is installed\u003c\/td\u003e\n\u003ctd\u003e°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperational temperature range without preheating\u003c\/td\u003e\n\u003ctd\u003e°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperational temperature range with preheating\u003c\/td\u003e\n\u003ctd\u003e°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions including packaging and pallet (w x h x d)\u003c\/td\u003e\n\u003ctd\u003emm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRelated products\u003c\/h3\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"\/en\/products\/dantherm-hcv-300\"\u003eVentilation system Dantherm Hcv 300\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"\/en\/products\/dantherm-hch-5\"\u003eVentilation system Dantherm Hch 5\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"\/en\/products\/master-pompa-idraulica-per-deumidificatori-dh-752-dh-792-dantherm-group\"\u003eCondensate pump for dehumidifiers DH 752, DH 792 Master Dantherm Group\u003c\/a\u003e \u0026mdash; from the category \u003ca href=\"\/en\/collections\/deumidificatori-e-pompe-di-calore\"\u003eDehumidifiers and Heat Pumps\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"\/en\/products\/master-tubo-flessibile-in-pvc-o230-mm-7-6-m-per-riscaldatori-b-18-dantherm-group\"\u003ePVC flexible hose – Ø230mm, 7.6m, for heaters B 18 Master Dantherm Group\u003c\/a\u003e \u0026mdash; from the category \u003ca href=\"\/en\/collections\/generatori-daria-calda-elettrici-e-a-gas\"\u003eElectric and Gas Hot Air Heaters\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"\/en\/products\/master-prolunga-16-a-10-m-per-riscaldatori-deumidificatori-e-ventilatori-dantherm-group\"\u003eExtension lead – 16 A \/ 10 m for Master heaters, dehumidifiers and fans, Dantherm Group\u003c\/a\u003e \u0026mdash; from the category \u003ca href=\"\/en\/collections\/spine-e-prese-uso-industriale-e-da-cantiere-heavy-duty-ip44-iec-60309-certificate-stagne-alta-protezione-ip67\"\u003eSite Electrical Equipment: Plugs, Sockets, Cables and Extension Leads\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003eBrowse the whole category: \u003ca href=\"\/en\/collections\/sistemi-di-ventilazione-e-griglie-areazione\"\u003eVentilation Systems, Air Grilles and Vents\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eBefore you order\u003c\/h3\u003e\n\u003cp\u003eTell us the quantities you need and the intended use: if there is a more suitable version, or an equivalent available sooner, we will let you know.\u003c\/p\u003e\n\u003cp\u003eFor prices and availability, \u003cstrong\u003erequest a quote from AMES Srl\u003c\/strong\u003e: we will reply with our quotation, delivery times and, where needed, an equivalent technical alternative.\u003c\/p\u003e","brand":"Dantherm Group","offers":[{"title":"Standard","offer_id":57763014541644,"sku":"dantherm-hch-8","price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/9864\/0716\/files\/Dantherm-HCH-8.jpg?v=1781107739","url":"https:\/\/www.amessrl.it\/en\/products\/dantherm-hch-8","provider":"A.M.E.S. srl","version":"1.0","type":"link"}