{"product_id":"dantherm-hcv-400-e1","title":"Ventilation system Dantherm Hcv 400 E1","description":"\u003ch2\u003eVentilation system Dantherm Hcv 400 E1\u003c\/h2\u003e\n\u003ch3\u003eWhat it is\u003c\/h3\u003e\n\u003cp\u003eVentilation system Dantherm Hcv 400 E1. Key specifications: max flow 330 V100Pa | m³\/h, max rated flow 240 Vmax.rated \/ m³\/h, recommended field of use 50 - 240 V | m³\/h.\u003c\/p\u003e\n\u003cp\u003eThese are air treatment units and components: fans, air purifiers, sanitising systems, heat pumps, ducting, grilles and ventilation fittings.\u003c\/p\u003e\n\u003ch3\u003eWhat it is for\u003c\/h3\u003e\n\u003cp\u003eUsed in air conditioning and air handling systems and for ventilating workplaces.\u003c\/p\u003e\n\u003ch3\u003eHow to use it\u003c\/h3\u003e\n\u003cp\u003eChoose the unit according to the room volume and place it on a stable base, with unobstructed air inlets and ducts as short and straight as possible. Use ozone generators only in rooms with no people or animals present, ventilating before re-entering. Clean or replace filters and grilles periodically.\u003c\/p\u003e\n\u003ch3\u003eWhere it is used\u003c\/h3\u003e\n\u003cul\u003e\u003cli\u003eResidential construction\u003c\/li\u003e\u003cli\u003eBuilding services\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eMax flow:\u003c\/strong\u003e 330 V100Pa | m³\/h\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eMax rated flow:\u003c\/strong\u003e 240 Vmax.rated \/ m³\/h\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eRecommended field of use:\u003c\/strong\u003e 50 - 240 V | m³\/h\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eEN 131417 reference flow 50pa:\u003c\/strong\u003e 168 VREF | m³\/h\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eThermal efficiency in accordance with EN 13141:\u003c\/strong\u003e 79 to 94 ηSUP | %\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eSpecific power consumption in accordance with:\u003c\/strong\u003e 0.20 SEL\/SYI | m³\/h\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eLeakage external and internal in accordance:\u003c\/strong\u003e \u0026lt;2% (Class A1) % | class\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eFilters according to EN 779:\u003c\/strong\u003e G4 (optional on supply: F7)\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eOutdoor temperature range without preheater i:\u003c\/strong\u003e -12 to +50 tODA | °C\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eOutdoor temperature range with preheater inst:\u003c\/strong\u003e -20 to +50 tODA | °C\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eSpigot\/duct connections:\u003c\/strong\u003e 160 – female Ø | mm\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eWeight (kg):\u003c\/strong\u003e 39\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eThermal conductivity, polystyrene insulation:\u003c\/strong\u003e 0.031 λ | W\/mK\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eHeat transition figures, polystyrene insulatio:\u003c\/strong\u003e \u0026lt;1 U | W\/m²K\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eWho it is for\u003c\/h3\u003e\n\u003cp\u003eDesigned for HVAC technicians and heating and plumbing engineers.\u003c\/p\u003e\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation ambient temperature\u003c\/td\u003e\n\u003ctd\u003etSURR  | °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor temperature range without preheater installed\u003c\/td\u003e\n\u003ctd\u003etODA | °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor temperature range with preheater installed\u003c\/td\u003e\n\u003ctd\u003etODA | °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum absolute humidity in extract air\u003c\/td\u003e\n\u003ctd\u003ex | g\/kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExterior dimensions (without wall brackets)\u003c\/td\u003e\n\u003ctd\u003ew x d x h | mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRelated products\u003c\/h3\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"\/en\/products\/dantherm-hcv-400-p1\"\u003eVentilation system Dantherm Hcv 400 P1\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"\/en\/products\/dantherm-hcv-300\"\u003eVentilation system Dantherm Hcv 300\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"\/en\/products\/master-dh-92-deumidificatori-a-condensazione-dantherm-group\"\u003eCondensation dehumidifier DH 92 Master Dantherm Group\u003c\/a\u003e \u0026mdash; from the category \u003ca href=\"\/en\/collections\/deumidificatori-e-pompe-di-calore\"\u003eDehumidifiers and Heat Pumps\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"\/en\/products\/master-uscita-2-vie-o230-mm-per-riscaldatori-b-18-dantherm-group\"\u003e2-way outlet – Ø230mm for B 18 heaters Master Dantherm Group\u003c\/a\u003e \u0026mdash; from the category \u003ca href=\"\/en\/collections\/generatori-daria-calda-elettrici-e-a-gas\"\u003eElectric and Gas Hot Air Heaters\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003e\u003ca href=\"\/en\/products\/master-prolunga-32-a-5-m-per-riscaldatori-b-15-b-18-b-22-dantherm-group\"\u003eExtension lead – 32 A \/ 5 m for Master B 15, B 18, B 22 heaters, Dantherm Group\u003c\/a\u003e \u0026mdash; from the category \u003ca href=\"\/en\/collections\/spine-e-prese-uso-industriale-e-da-cantiere-heavy-duty-ip44-iec-60309-certificate-stagne-alta-protezione-ip67\"\u003eSite Electrical Equipment: Plugs, Sockets, Cables and Extension Leads\u003c\/a\u003e\u003c\/li\u003e\u003cli\u003eBrowse the whole category: \u003ca href=\"\/en\/collections\/sistemi-di-ventilazione-e-griglie-areazione\"\u003eVentilation Systems, Air Grilles and Vents\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eBefore you order\u003c\/h3\u003e\n\u003cp\u003eTell us the quantities you need and the intended use: if there is a more suitable version, or an equivalent available sooner, we will let you know.\u003c\/p\u003e\n\u003cp\u003eFor prices and availability, \u003cstrong\u003erequest a quote from AMES Srl\u003c\/strong\u003e: we will reply with our quotation, delivery times and, where needed, an equivalent technical alternative.\u003c\/p\u003e","brand":"Dantherm Group","offers":[{"title":"Standard","offer_id":57763014771020,"sku":"dantherm-hcv-400-e1","price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0926\/9864\/0716\/files\/Dantherm-HCV-400.jpg?v=1781107741","url":"https:\/\/www.amessrl.it\/en\/products\/dantherm-hcv-400-e1","provider":"A.M.E.S. srl","version":"1.0","type":"link"}