Dehumidifier Dantherm CDP 50
Key features
- Working temperature range10–36 °C
- Dehumidifying capacity at 30 °C/60% RH53,2 l/24h
- Dehumidifying capacity at 20 °C/60% RH29,7 l/24h
- Specific energy consumption at 30°C/60°C0.47 kWh/l
- Specific energy consumption at 20°C/60°C0.61 kWh/l
- Air flow rate (m³/h)680
What it is
Dehumidifier Dantherm CDP 50. Key specifications: working temperature range 10–36 °C, dehumidifying capacity at 30 °C/60% RH 53,2 l/24h, dehumidifying capacity at 20 °C/60% RH 29,7 l/24h.
Dehumidifiers and heat pumps are units that extract moisture from the air to dry rooms, building sites and indoor swimming pools, or heat pool water.
What it is for
Used for air conditioning indoor spaces, for dehumidifying rooms and structures and for dehumidifying indoor spaces.
How to use it
Stand the unit level, away from walls to allow air to circulate, and close the doors and windows of the room being treated. Set the desired humidity level or temperature and drain the condensate into the tank or through a hose to a drain. Clean the air filter regularly; install and connect fixed units and heat pumps as described in the manual.
Where it is used
- Building services
- Building maintenance
- Renovation
Technical data
- Working temperature range: 10–36 °C
- Dehumidifying capacity at 30 °C/60% RH: 53,2 l/24h
- Dehumidifying capacity at 20 °C/60% RH: 29,7 l/24h
- Specific energy consumption at 30°C/60°C: 0.47 kWh/l
- Specific energy consumption at 20°C/60°C: 0.61 kWh/l
- Air flow rate (m³/h): 680
- Weight of R454C gas, CO2 equivalent: 0,8/0,12 kg/t
- Max current (A): 5,8
- Energy consumption at 30°C/60°C (kW): 1
- Energy consumption at 20°C/60°C (kW): 0,8
- Max energy consumption with electric heater (kW): 4,9
- Heat recovered at 30 °C/60% RH (kW): 2,7
- Heat recovered at 20 °C/60% RH (kW): 1,6
- Filter type: PPI 15
Who it is for
Designed for industrial maintenance technicians and HVAC technicians.
Technical specifications
| Specification | Value |
|---|---|
| Operating range - temperature | °C |
| Operating range - humidity | % RH |
| Dehumidification capacity at 30 °C/60% | l/24h |
| Dehumidification capacity at 20 °C/60% | l/24h |
| Specific energy consumption at 30 °C/60% | kWh/l |
| Specific energy consumption at 20 °C/60% | kWh/l |
| Air flow rate | m³/h |
| Noise level at 1 m | dB(A) |
| R454C gas weight / CO₂ equivalent | kg/t |
| Power supply | V/Hz |
| Current, max. | A |
| Power consumption, max. | kW |
| Power consumption at 30 °C/60% | kW |
| Power consumption at 20 °C/60% | kW |
| Power consumption, max., with electric heater | kW |
| Product dimensions (W x D x H) | mm |
| Weight | kg |
Related products
- Dehumidifier Dantherm CDP 50T
- Dehumidifier Dantherm CDP 40T
- PVC flexible hose – Ø230mm, 7.6m, for heaters B 18 Master Dantherm Group — from the category Electric and Gas Hot Air Heaters
- Multi-purpose pool concentrate FP Crystal Firma Chimica — from the category Swimming Pools and Accessories
- Extension lead – 16 A / 10 m for Master heaters, dehumidifiers and fans, Dantherm Group — from the category Site Electrical Equipment: Plugs, Sockets, Cables and Extension Leads
- Browse the whole category: Dehumidifiers and Heat Pumps
Before you order
In your request, please state the rated load or flow rate and the quantities required, so we can give you the right quotation first time.
For prices and availability, request a quote from AMES Srl: we will reply with our quotation, delivery times and, where needed, an equivalent technical alternative.
Specifications 15
| Working temperature range | 10–36 °C |
|---|---|
| Dehumidifying capacity at 30 °C/60% RH | 53,2 l/24h |
| Dehumidifying capacity at 20 °C/60% RH | 29,7 l/24h |
| Specific energy consumption at 30°C/60°C | 0.47 kWh/l |
| Specific energy consumption at 20°C/60°C | 0.61 kWh/l |
| Air flow rate (m³/h) | 680 |
| Weight of R454C gas, CO2 equivalent | 0,8/0,12 kg/t |
| Max current (A) | 5,8 |
| Energy consumption at 30°C/60°C (kW) | 1 |
| Energy consumption at 20°C/60°C (kW) | 0,8 |
| Max energy consumption with electric heater (kW) | 4,9 |
| Heat recovered at 30 °C/60% RH (kW) | 2,7 |
| Heat recovered at 20 °C/60% RH (kW) | 1,6 |
| Filter type | PPI 15 |
| Protection class | IPX4 |
The perfect setup for this job
Everything you need in one place, from functionality to safety.
For the job
Measure temperature and humidity to monitor conditions in the work environment.
Measure voltage, current, humidity and gas for checks and diagnostics on site and in maintenance.
Renew, filter and purify the air in rooms with fans, ducts and grilles.