Pump out muddy water with sand and debris from excavations, sumps and flooded rooms.

Lifting station for aerobic leachate treatment Rototec
Also known as: pumping station, lift station
Key features
- TypeUnderground lift station for aerobic trickling filter
- Materialhigh-density polyethylene, PVC inlet pipe, polyethylene outlet
- Diameter (mm)500
- Height (mm)NSOLMG2300: 2300; NSOLMG2700: 2700; NSOLMG3000: 3000
- Inlet diameter (mm)125
- Outlet diameter (mm)50
What it is
The lifting station for aerobic trickling filters is an underground LLDPE tank with a submersible electric pump with recessed impeller, designed to feed an aerobic trickling filter when gravity discharge is not possible (domestic and similar users, small/medium installations). Applications: feeding aerobic trickling filters, domestic/similar discharges, scattered residential, hospitality, campsites, communities/services, integration into existing treatment lines. Features: vertical cylindrical high-density polyethylene (HDPE) container, PVC inlet pipe (Ø 125 mm) with NBR rubber seal, submersible electric pump with recessed impeller, polyethylene outlet pipe (Ø 50 mm), float for automatic start/stop.
Wastewater treatment systems are tanks, treatment units, pumping stations and components such as blowers, diffusers, control panels and covers for treating and pumping wastewater.
What it is for
Used in the installation and maintenance of plumbing systems and for pumping water out of excavations, tanks and sumps.
How to use it
Bury the tanks on a level bedding layer, connect inlet and outlet at the correct falls and backfill while gradually filling them with water to balance the soil pressure. Have blowers, pumps and control panels connected by an electrician and keep them protected from water. Inspect the system through the covers, clean the diffusers and have the sludge emptied regularly.
Where it is used
- Building services
- Water engineering works
Technical data
- Type: Underground lift station for aerobic trickling filter
- Material: high-density polyethylene, PVC inlet pipe, polyethylene outlet
- Diameter (mm): 500
- Height (mm): NSOLMG2300: 2300; NSOLMG2700: 2700; NSOLMG3000: 3000
- Inlet diameter (mm): 125
- Outlet diameter (mm): 50
- Inspection diameter (mm): 400
- Pump: PNRG01G, submersible electric pump with vortex impeller and float switch
- Voltage (V): 230
- Flow rate (l/min): 10-140
- Head (m): 6-1
Who it is for
Designed for plumbers.
Related products
- Lifting station Pico Sol, single pump, Rototec
- Lifting station Ennesol, double pump, Rototec
- Round inspection chamber with tap — from the category Inspection Chambers
- Submersible pump for heavily soiled water DXG inox Wortex — from the category Submersible Wastewater Pumps
- Site socket outlet board Friggeri PS-DS001002024SP — from the category Distribution Boards and Protection Devices
- Browse the whole category: Water Purification
Before you order
In your request, please state the diameter, the supply voltage, the rated load or flow rate and the quantities required, so we can give you the right quotation first time.
For prices and availability, request a quote from AMES Srl: we will reply with our quotation, delivery times and, where needed, an equivalent technical alternative.
Specifications 11
| Type | Underground lift station for aerobic trickling filter |
|---|---|
| Material | high-density polyethylene, PVC inlet pipe, polyethylene outlet |
| Diameter (mm) | 500 |
| Height (mm) | NSOLMG2300: 2300; NSOLMG2700: 2700; NSOLMG3000: 3000 |
| Inlet diameter (mm) | 125 |
| Outlet diameter (mm) | 50 |
| Inspection diameter (mm) | 400 |
| Pump | PNRG01G, submersible electric pump with vortex impeller and float switch |
| Voltage (V) | 230 |
| Flow rate (l/min) | 10-140 |
| Head (m) | 6-1 |
Technical documents
Manufacturer documents (PDF, opens in a new tab).
Compare with other products in Water purification and treatment
Technical data declared by the manufacturers. A dash means the figure is not declared.
| Feature |
This model
Lifting station for aerobic leachate treatment Rototec
|
Anti-flood inspection chamber Rototec
|
Screw-type extension for underground tanks Rototec
|
Hinged extension for underground tanks Rototec
|
|---|---|---|---|---|
| Brand | Rototec | Rototec | Rototec | Rototec |
| Type | Underground lift station for aerobic trickling filter | Not declared | Screw extension for underground tanks | Not declared |
| Material | high-density polyethylene, PVC inlet pipe, polyethylene outlet | One-piece LLDPE; trafficable high-density PVC grating; PE outlet | one-piece linear LLDPE polyethylene | Linear polyethylene (LLDPE) monobloc |
| Diameter (mm) | 500 | 660 | PP30: 300; PP35: 435; PP35RIM: 300; PP45: 535; PP60RIM: 535 | 750 |
| Height (mm) | NSOLMG2300: 2300; NSOLMG2700: 2700; NSOLMG3000: 3000 | Not declared | 300 | Not declared |
| Inspection diameter (mm) | 400 | Not declared | PP30: 210; PP35: 300; PP35RIM: 210; PP45: 400; PP60RIM: 400 | 630 |
| Pump | PNRG01G, submersible electric pump with vortex impeller and float switch | PNRG01 with electric float switch and non-return valve | Not declared | Not declared |
| Flow rate (l/min) | 10-140 | 20-155 | Not declared | Not declared |
| Outlet diameter (mm) | 50 | 50 | Not declared | Not declared |
| View product | View product → | View product → | View product → |
The perfect setup for this job
Everything you need in one place, from functionality to safety.
For the job
Eliminate or mask bad odours from portable toilets, waste, drains and rooms.
Distribute power on site and protect people and tools from overloads and earth leakage.
For safety
Protect hands from cuts, impacts, heat, cold and chemicals.