Skip to content
0 Quotes 0Compare
All Rototec products

Lifting station for aerobic leachate treatment Rototec

Also known as: pumping station, lift station

Key features

  • TypeUnderground lift station for aerobic trickling filter
  • Materialhigh-density polyethylene, PVC inlet pipe, polyethylene outlet
  • Diameter (mm)500
  • Height (mm)NSOLMG2300: 2300; NSOLMG2700: 2700; NSOLMG3000: 3000
  • Inlet diameter (mm)125
  • Outlet diameter (mm)50
See all 11 specifications

What it is

The lifting station for aerobic trickling filters is an underground LLDPE tank with a submersible electric pump with recessed impeller, designed to feed an aerobic trickling filter when gravity discharge is not possible (domestic and similar users, small/medium installations). Applications: feeding aerobic trickling filters, domestic/similar discharges, scattered residential, hospitality, campsites, communities/services, integration into existing treatment lines. Features: vertical cylindrical high-density polyethylene (HDPE) container, PVC inlet pipe (Ø 125 mm) with NBR rubber seal, submersible electric pump with recessed impeller, polyethylene outlet pipe (Ø 50 mm), float for automatic start/stop.

Wastewater treatment systems are tanks, treatment units, pumping stations and components such as blowers, diffusers, control panels and covers for treating and pumping wastewater.

What it is for

Used in the installation and maintenance of plumbing systems and for pumping water out of excavations, tanks and sumps.

How to use it

Bury the tanks on a level bedding layer, connect inlet and outlet at the correct falls and backfill while gradually filling them with water to balance the soil pressure. Have blowers, pumps and control panels connected by an electrician and keep them protected from water. Inspect the system through the covers, clean the diffusers and have the sludge emptied regularly.

Where it is used

  • Building services
  • Water engineering works

Technical data

  • Type: Underground lift station for aerobic trickling filter
  • Material: high-density polyethylene, PVC inlet pipe, polyethylene outlet
  • Diameter (mm): 500
  • Height (mm): NSOLMG2300: 2300; NSOLMG2700: 2700; NSOLMG3000: 3000
  • Inlet diameter (mm): 125
  • Outlet diameter (mm): 50
  • Inspection diameter (mm): 400
  • Pump: PNRG01G, submersible electric pump with vortex impeller and float switch
  • Voltage (V): 230
  • Flow rate (l/min): 10-140
  • Head (m): 6-1

Who it is for

Designed for plumbers.

Related products

Before you order

In your request, please state the diameter, the supply voltage, the rated load or flow rate and the quantities required, so we can give you the right quotation first time.

For prices and availability, request a quote from AMES Srl: we will reply with our quotation, delivery times and, where needed, an equivalent technical alternative.

Quantity
Specifications 11
TypeUnderground lift station for aerobic trickling filter
Materialhigh-density polyethylene, PVC inlet pipe, polyethylene outlet
Diameter (mm)500
Height (mm)NSOLMG2300: 2300; NSOLMG2700: 2700; NSOLMG3000: 3000
Inlet diameter (mm)125
Outlet diameter (mm)50
Inspection diameter (mm)400
PumpPNRG01G, submersible electric pump with vortex impeller and float switch
Voltage (V)230
Flow rate (l/min)10-140
Head (m)6-1

Technical documents

Manufacturer documents (PDF, opens in a new tab).

Compare with other products in Water purification and treatment

Technical data declared by the manufacturers. A dash means the figure is not declared.

Technical data compared across products of the collection: Water purification and treatment
Feature This model Lifting station for aerobic leachate treatment Rototec Anti-flood inspection chamber Rototec Screw-type extension for underground tanks Rototec Hinged extension for underground tanks Rototec
Brand RototecRototecRototecRototec
TypeUnderground lift station for aerobic trickling filterNot declaredScrew extension for underground tanksNot declared
Materialhigh-density polyethylene, PVC inlet pipe, polyethylene outletOne-piece LLDPE; trafficable high-density PVC grating; PE outletone-piece linear LLDPE polyethyleneLinear polyethylene (LLDPE) monobloc
Diameter (mm)500660PP30: 300; PP35: 435; PP35RIM: 300; PP45: 535; PP60RIM: 535750
Height (mm)NSOLMG2300: 2300; NSOLMG2700: 2700; NSOLMG3000: 3000Not declared300Not declared
Inspection diameter (mm)400Not declaredPP30: 210; PP35: 300; PP35RIM: 210; PP45: 400; PP60RIM: 400630
PumpPNRG01G, submersible electric pump with vortex impeller and float switchPNRG01 with electric float switch and non-return valveNot declaredNot declared
Flow rate (l/min)10-14020-155Not declaredNot declared
Outlet diameter (mm)5050Not declaredNot declared