Pump out muddy water with sand and debris from excavations, sumps and flooded rooms.

Activated sludge treatment plant DEP RF with sludge recirculation Rototec
Also known as: sewage treatment plant, wastewater treatment plant
Key features
- Typeanaerobic trickling filter + low-load activated sludge plant with air-lift sludge recirculation
- Materialcorrugated polyethylene (PE)
- StandardUNI EN 12566-3; Italian Legislative Decree 152/2006 (limits in Table 4, Annex 5)
- Equipment suppliedBlower-compressors, micro-bubble diffusers, outlet housing for chlorine tablet
- UseAdvanced secondary treatment of municipal wastewater
What it is
The system is a biological module consisting of an anaerobic trickling filter plus low-load activated sludge with air-lift recirculation, for domestic or equivalent users and small communities. It makes it possible to meet the limits of Table 4 - Annex 5, Italian Legislative Decree 152/2006. It includes blowers/diaphragm compressors, fine-bubble diffusers and an outlet chlorine housing for disinfection where required; application: advanced secondary treatment of domestic wastewater.
Wastewater treatment systems are tanks, treatment units, pumping stations and components such as blowers, diffusers, control panels and covers for treating and pumping wastewater.
What it is for
Used for filtering system water and in the installation and maintenance of plumbing systems.
How to use it
Bury the tanks on a level bedding layer, connect inlet and outlet at the correct falls and backfill while gradually filling them with water to balance the soil pressure. Have blowers, pumps and control panels connected by an electrician and keep them protected from water. Inspect the system through the covers, clean the diffusers and have the sludge emptied regularly.
Where it is used
- Building services
- Water engineering works
Technical data
- Material: corrugated polyethylene (PE)
- Standard: UNI EN 12566-3; Italian Legislative Decree 152/2006 (limits in Table 4, Annex 5)
- Equipment supplied: Blower-compressors, micro-bubble diffusers, outlet housing for chlorine tablet
- Use: Advanced secondary treatment of municipal wastewater
Who it is for
Designed for plumbers.
Standards and safety
UNI EN 12566 3 UNI EN 12566 1 Italian Legislative Decree 152/06 (part 3) Resolution of the Interministerial Committee for the Protection of Waters no. 48/77 Table 4 Annex 5 (Italian Legislative Decree 152/2006) Regulation 305/11
Related products
- Dual-stage anaerobic treatment plant Rototec
- Activated sludge treatment plant DEP for Table 4 discharge Rototec
- Rectangular inspection chamber — from the category Inspection Chambers
- Submersible pump for heavily soiled water DXG 1000/1200 Wortex — from the category Submersible Wastewater Pumps
- Transformer Friggeri TR-750/2 — from the category Distribution Boards and Protection Devices
- Browse the whole category: Water Purification
Before you order
Tell us the quantities you need and the intended use: if there is a more suitable version, or an equivalent available sooner, we will let you know.
For prices and availability, request a quote from AMES Srl: we will reply with our quotation, delivery times and, where needed, an equivalent technical alternative.
Specifications 5
| Type | anaerobic trickling filter + low-load activated sludge plant with air-lift sludge recirculation |
|---|---|
| Material | corrugated polyethylene (PE) |
| Standard | UNI EN 12566-3; Italian Legislative Decree 152/2006 (limits in Table 4, Annex 5) |
| Equipment supplied | Blower-compressors, micro-bubble diffusers, outlet housing for chlorine tablet |
| Use | Advanced secondary treatment of municipal wastewater |
Technical documents
Manufacturer documents (PDF, opens in a new tab).
Compare with other products in Water purification and treatment
Technical data declared by the manufacturers. A dash means the figure is not declared.
| Feature |
This model
Activated sludge treatment plant DEP RF with sludge recirculation Rototec
|
Grease separator in polyethylene for greywater UNI EN 1825-1 Rototec
|
First-flush storage system, soil discharge, TAB.4, Rototec
|
Oil alarm device Rototec
|
|---|---|---|---|---|
| Brand | Rototec | Rototec | Rototec | Rototec |
| Material | corrugated polyethylene (PE) | Polyethylene | Polyethylene tanks (smooth, corrugated or modular, depending on model) | Not declared |
| Standard | UNI EN 12566-3; Italian Legislative Decree 152/2006 (limits in Table 4, Annex 5) | UNI EN 1825-1, D.Lgs 152/2006, marcatura CE Reg. 305/11 | Discharge to soil, Table 4 of Legislative Decree 152/2006 | ATEX/EX approved probe |
| Equipment supplied | Blower-compressors, micro-bubble diffusers, outlet housing for chlorine tablet | Not declared | Not declared | Blow-moulded PE probe/float switch, wall-mounted audible-visual alarm, 2 independent relay outputs |
| Use | Advanced secondary treatment of municipal wastewater | Acque grigie di cucine professionali, mense, laboratori alimentari (escluse acque meteoriche) | run-off water from car parks, roads, yards and storage areas | oil-level alarm in oil separators/hydrocarbon separators |
| View product | View product → | View product → | View product → |
The perfect setup for this job
Everything you need in one place, from functionality to safety.
For the job
Eliminate or mask bad odours from portable toilets, waste, drains and rooms.
Distribute power on site and protect people and tools from overloads and earth leakage.
For safety
Protect hands from cuts, impacts, heat, cold and chemicals.