Carry water for irrigating, washing and supplying machines in the garden and on site.

Dantherm AC air cooling system Dantherm Group 15000
Key features
- Cooling capacity at 25°C indoor/outdoor15000 / 51240 W | Btu/h
- Air flow rate, min max level (m³/h)2000 / 3000
- Boost air flow rate (m³/h)3450
- Internal fan speed5+1
- Internal fan modeCooling, ventilation, automatic
- Outdoor unit air volume (m³/h)6700
What it is
Dantherm AC air cooling system Dantherm Group 15000. Key specifications: cooling capacity at 25°C indoor/outdoor 15000 / 51240 W | Btu/h, air flow rate, min max level (m³/h) 2000 / 3000, boost air flow rate (m³/h) 3450.
An industrial cooler is a portable air conditioner, evaporative cooler or fan that lowers the temperature or moves air in warehouses, construction sites and plant rooms.
What it is for
Used for air conditioning industrial premises, for dehumidifying indoor spaces and for ventilating workplaces.
How to use it
Place portable air conditioners near an opening, with the hot air hose venting outside and the condensate drain connected or emptied; fill evaporative coolers with clean water. Set fans down securely, with the guard intact, directing the airflow towards workstations. Clean filters and grilles regularly and connect the units to protected sockets.
Where it is used
- Events and exhibition fit-out
- Mechanical engineering industry
- Logistics and warehousing
Technical data
- Cooling capacity at 25°C indoor/outdoor: 15000 / 51240 W | Btu/h
- Air flow rate, min max level (m³/h): 2000 / 3000
- Boost air flow rate (m³/h): 3450
- Internal fan speed: 5+1
- Internal fan mode: Cooling, ventilation, automatic
- Outdoor unit air volume (m³/h): 6700
- Min/max operating temperature, outdoor unit: -5 / +47 °C
- Min/max operating temperature, indoor unit: +5 / +37 °C
- Recommended fuses (A): 16
- Indoor/outdoor unit protection class: IP22 / IP24
- Connection plug from indoor unit to: 16 A three-phase & N & E
- Connection plug between indoor unit and outdoor unit: 3-pole Harting plug, Type
- Global warming potential factor: 148 GWP
- CO2 equivalent: 0.355 t
Who it is for
Designed for industrial maintenance technicians and HVAC technicians.
Technical specifications
| Feature | Value |
|---|---|
| Cooling capacity at 25 °C indoor/outdoor | W | Btu/h |
| Maximum cooling capacity | W | Btu/h |
| Power consumption | W max |
| Air flow rate - min./max. level | m³/h |
| Air flow rate - boost | m³/h |
| Air volume - outdoor unit | m³/h |
| Noise level at 1 m (indoor unit) | dB(A) |
| Noise level at 3 m (outdoor unit), max. | dB(A) |
| Operating temperature min./max. – outdoor unit | °C |
| Operating temperature min./max. – indoor unit | °C |
| Power supply | V | ph | Hz |
| Protection rating – indoor/outdoor unit | - |
| Indoor unit power plug | - |
| Refrigerant | Type | g |
| Global warming potential factor | GWP |
| Suction-side pressure, max. | MPa |
| Discharge-side pressure, max. | MPa |
| Maximum operating pressure | MPa |
| Product dimensions without packaging (L × D × H) | mm |
| Weight without packaging | kg |
Related products
- Dantherm AC air cooling system Dantherm Group 7000
- Biocool Bio air cooling system Dantherm Group Exh
- Dehumidifier Dantherm CDP 70 — from the category Dehumidifiers and Heat Pumps
- Electrical distribution box with 4 sockets Aerial CC4 MID Dantherm Group — from the category Site Electrical Equipment: Plugs, Sockets, Cables and Extension Leads
- Trotec Tfv 900 ventilation system Dantherm Group — from the category Ventilation Systems, Air Grilles and Vents
- Browse the whole category: Industrial Space Coolers
Before you order
In your request, please state the power rating, the rated load or flow rate and the quantities required, so we can give you the right quotation first time.
For prices and availability, request a quote from AMES Srl: we will reply with our quotation, delivery times and, where needed, an equivalent technical alternative.
Specifications 17
| Cooling capacity at 25°C indoor/outdoor | 15000 / 51240 W | Btu/h |
|---|---|
| Air flow rate, min-max level (m³/h) | 2000 / 3000 |
| Boost air flow rate (m³/h) | 3450 |
| Internal fan speed | 5+1 |
| Internal fan mode | Cooling, ventilation, automatic |
| Outdoor unit air volume (m³/h) | 6700 |
| Min/max operating temperature, outdoor unit | -5 / +47 °C |
| Min/max operating temperature, indoor unit | +5 / +37 °C |
| Recommended fuses (A) | 16 |
| Indoor/outdoor unit protection class | IP22 / IP24 |
| Connection plug from indoor unit to | 16 A three-phase & N & E |
| Connection plug between indoor unit and outdoor unit | 3-pole Harting plug, Type |
| Global warming potential factor | 148 GWP |
| CO2 equivalent | 0.355 t |
| Fluid type | Water / 35% ethylene glycol mixture, Type |
| Fluid quantity (L) | 10 |
| Product dimensions without packaging L P (mm) | 1175 × 601 × 1315 |
The perfect setup for this job
Everything you need in one place, from functionality to safety.
For the job
Renew, filter and purify the air in rooms with fans, ducts and grilles.
Bring power to site tools through protected connections, including outdoors.