Skip to content
0 Quotes 0Compare
All Irudek products

Multiple docking station for gas detectors Irudek SGT / MGT

Key features

  • Dimensions (mm)525 x 437 x 213
  • Weight (kg)11
  • BatteryRechargeable Li-Ion, 1,000 bump tests
  • Memory8 GB
  • Power supplyDC 12 V, 3 A
  • Operating temperature+5 / +40 °C
See all 8 specifications

What it is

Multiple docking station for gas detectors Irudek SGT / MGT. Key specifications: dimensions (mm) 525 x 437 x 213, weight (kg) 11, battery Rechargeable Li-Ion, 1,000 bump tests.

The docking station is a base on which the gas detector is placed for recharging; depending on the model, it can also automatically perform the alarm check and sensor calibration.

What it is for

Used for inspecting plant, pipework and structures and for workplace safety, as equipment required by the safety plan.

How to use it

Power the base with the cable provided and place the detector on it switched off, or as the manufacturer indicates. When charging or testing is complete, remove the instrument. Keep it on a stable surface, away from water and dust.

Where it is used

  • Chemical industry
  • Workplace safety and PPE

Technical data

  • Dimensions (mm): 525 x 437 x 213
  • Weight (kg): 11
  • Battery: Rechargeable Li-Ion, 1,000 bump tests
  • Memory: 8 GB
  • Power supply: DC 12 V, 3 A
  • Operating temperature: +5 / +40 °C
  • Gas: SGT: CO, H2S, O2, SO2, H2, NH3; MGT: LEL, CO, H2S, O2
  • Capacity: MGT: up to 4 detectors

Who it is for

Designed for industrial maintenance technicians and health and safety officers.

Related products

Before you order

Tell us the quantities you need and the intended use: if there is a more suitable version, or an equivalent available sooner, we will let you know.

For prices and availability, request a quote from AMES Srl: we will reply with our quotation, delivery times and, where needed, an equivalent technical alternative.

Quantity
Specifications 8
Dimensions (mm)525 x 437 x 213
Weight (kg)11
BatteryRechargeable Li-Ion, 1,000 bump tests
Memory8 GB
Power supplyDC 12 V, 3 A
Operating temperature+5 / +40 °C
GasSGT: CO, H2S, O2, SO2, H2, NH3; MGT: LEL, CO, H2S, O2
CapacityMGT: up to 4 detectors

The perfect setup for this job

Everything you need in one place, from functionality to safety.

For the job

A.M.E.S. srlBattery smoke detector

Put out incipient fires with powder, water or carbon dioxide.

For safety

IrudekHarness Light 1, IrudekCode 100404500053

Protect against falls from height by supporting the body during work at height.