Seal joints and gaps against water, air and dust and fix components without screws.

Ventilation system Dantherm Hcv 400 P1
Key features
- Max rated flow rate at 100 Pa250 V | m³/h
- Recommended working range50 - 250 V | m³/h
- EN 131417 reference flow rate175 VREF | m³/h
- Thermal efficiency per EN 13141792 ηSUP | %
- Specific energy consumption according to the standard0.23 SFP | m³/h
- Internal and external leakage to the standard<2% (Class A1) %
What it is
Ventilation system Dantherm Hcv 400 P1. Key specifications: max rated flow rate at 100 Pa 250 V | m³/h, recommended working range 50 - 250 V | m³/h, EN 131417 reference flow rate 175 VREF | m³/h.
These are air treatment units and components: fans, air purifiers, sanitising systems, heat pumps, ducting, grilles and ventilation fittings.
What it is for
Used in air conditioning and air handling systems and for ventilating workplaces.
How to use it
Choose the unit according to the room volume and place it on a stable base, with unobstructed air inlets and ducts as short and straight as possible. Use ozone generators only in rooms with no people or animals present, ventilating before re-entering. Clean or replace filters and grilles periodically.
Where it is used
- Residential construction
- Building services
Technical data
- Max rated flow rate at 100 Pa: 250 V | m³/h
- Recommended working range: 50 - 250 V | m³/h
- EN 131417 reference flow rate: 175 VREF | m³/h
- Thermal efficiency per EN 131417: 92 ηSUP | %
- Specific energy consumption according to the standard: 0.23 SFP | m³/h
- Internal and external leakage to the standard: <2% (Class A1) %
- Filters compliant with EN 779: G4 (optional on supply air: F7)
- Installation area temperature: +12 to +50 tSURR | °C
- Outdoor temperature without pre heater installed: -12 to +50 tODA | °C
- Outdoor temperature with pre heater installed: -20 to +50 tODA | °C
- Maximum absolute humidity in extracted air: 10 x | g/kg
- Grille/duct connections: 160 – female Ømm
- Thermal conductivity of polystyrene insulation: 0,031 λ | W/mK
- Thermal transition values, insulation in p: <1 U | W/m²K
Who it is for
Designed for HVAC technicians and heating and plumbing engineers.
Technical specifications
| Feature | Value |
|---|---|
| Maximum air flow at 100 Pa | V | m³/h |
| EN 13141-7 reference flow rate | VREF | m³/h |
| Specific energy consumption according to EN13141-7 | SFP | m³/h |
| Installation area temperature | tSURR | °C |
| Outdoor temperature without preheater installed | tODA | °C |
| Outdoor temperature with preheater installed | tODA | °C |
| Maximum absolute humidity in extract air | x | g/kg |
| External dimensions without wall brackets | w x d x h | mm |
| Weight | kg |
| Voltage | U | V |
| Maximum power consumption without/with preheating | P | W |
| Frequency | f | Hz |
| Protection rating | - |
Related products
- Ventilation system Dantherm Hcv 400 P2
- Ventilation system Dantherm Hcv 400 E1
- Dehumidifier Dantherm CDP 40T — from the category Dehumidifiers and Heat Pumps
- 2-way outlet – Ø230mm for B 18 heaters Master Dantherm Group — from the category Electric and Gas Hot Air Heaters
- Extension lead – 16 A / 10 m for Master heaters, dehumidifiers and fans, Dantherm Group — from the category Site Electrical Equipment: Plugs, Sockets, Cables and Extension Leads
- Browse the whole category: Ventilation Systems, Air Grilles and Vents
Before you order
In your request, please state the rated load or flow rate and the quantities required, so we can give you the right quotation first time.
For prices and availability, request a quote from AMES Srl: we will reply with our quotation, delivery times and, where needed, an equivalent technical alternative.
Specifications 19
| Max rated flow rate at 100 Pa | 250 V | m³/h |
|---|---|
| Recommended working range | 50 - 250 V | m³/h |
| EN 131417 reference flow rate | 175 VREF | m³/h |
| Thermal efficiency per EN 131417 | 92 ηSUP | % |
| Specific energy consumption according to the standard | 0.23 SFP | m³/h |
| Internal and external leakage to the standard | <2% (Class A1) % |
| Filters compliant with EN 779 | G4 (optional on supply air: F7) |
| Installation area temperature | +12 to +50 tSURR | °C |
| Outdoor temperature without pre-heater installed | -12 to +50 tODA | °C |
| Outdoor temperature with pre-heater installed | -20 to +50 tODA | °C |
| Maximum absolute humidity in extracted air | 10 x | g/kg |
| Grille/duct connections | 160 – female Ømm |
| Thermal conductivity of polystyrene insulation | 0,031 λ | W/mK |
| Thermal transition values, insulation in p | <1 U | W/m²K |
| Insulation reaction to fire classification | DIN 4102-1 class B2 EN 13501 class E |
| Drain hose | ¾ / 1 Ø/length | "/mm |
| Structure colour | 9016 / RAL grey galvanised metal |
| Maximum energy consumption without/with preheating | 170/1.570 P | W |
| Protection class | IP21 |
The perfect setup for this job
Everything you need in one place, from functionality to safety.
For the job
Fix, assemble, repair and seal without screws or glue on wood, metal and walls.
Fix medium and light items to walls by expanding in the hole.
Cut wide holes in concrete, masonry and tiles for pipes, electrical boxes and openings.




