Skip to content
0 Quotes 0Compare
All Dantherm Group products

Ventilation system Dantherm Hcv 400 P2

Code dantherm-hcv-400-p2

Key features

  • Max flow at 100Pa330 V | m³/h
  • Max rated flow240 V | m³/h
  • Recommended field of use50 - 240 V | m³/h
  • EN 131417 reference flow at 50pa168 VREF | m³/h
  • Thermal efficiency in accordance with EN 1314191 ηSUP | %
  • Specific power consumption in accordance with0.20 SFP | m³/h
See all 20 specifications

What it is

Ventilation system Dantherm Hcv 400 P2. Key specifications: max flow at 100Pa 330 V | m³/h, max rated flow 240 V | m³/h, recommended field of use 50 - 240 V | m³/h.

These are air treatment units and components: fans, air purifiers, sanitising systems, heat pumps, ducting, grilles and ventilation fittings.

What it is for

Used in air conditioning and air handling systems and for ventilating workplaces.

How to use it

Choose the unit according to the room volume and place it on a stable base, with unobstructed air inlets and ducts as short and straight as possible. Use ozone generators only in rooms with no people or animals present, ventilating before re-entering. Clean or replace filters and grilles periodically.

Where it is used

  • Residential construction
  • Building services

Technical data

  • Max flow at 100Pa: 330 V | m³/h
  • Max rated flow: 240 V | m³/h
  • Recommended field of use: 50 - 240 V | m³/h
  • EN 131417 reference flow at 50pa: 168 VREF | m³/h
  • Thermal efficiency in accordance with EN 13141: 91 ηSUP | %
  • Specific power consumption in accordance with: 0.20 SFP | m³/h
  • Leakage external and internal in accordance: <2% (Class A1) %
  • Filters according to EN 779: G4 (optional on supply: F7)
  • Outdoor temperature without preheater install: -12 to +50 tODA | °C
  • Spigot/duct connections: 160 – female Ømm
  • Weight (kg): 39
  • Thermal conductivity, polystyrene insulation: 0,031 λ | W/mK
  • Heat transition figures, polystyrene insulatio: <1 U | W/m²K
  • Insulation reaction to fire class: DIN 4102-1 class B2 EN 13501 class E

Who it is for

Designed for HVAC technicians and heating and plumbing engineers.

Technical specifications

Feature Value
Installation ambient temperature tSURR | °C
Outdoor temperature without preheater installed tODA | °C
Outdoor temperature with preheater installed tODA | °C
Maximum absolute humidity in extract air x | g/kg
Dimensions (without wall bracket) w x d x h | mm

Related products

Before you order

Tell us the quantities you need and the intended use: if there is a more suitable version, or an equivalent available sooner, we will let you know.

For prices and availability, request a quote from AMES Srl: we will reply with our quotation, delivery times and, where needed, an equivalent technical alternative.

Quantity
Specifications 20
Max flow at 100Pa330 V | m³/h
Max rated flow240 V | m³/h
Recommended field of use50 - 240 V | m³/h
EN 131417 reference flow at 50pa168 VREF | m³/h
Thermal efficiency in accordance with EN 1314191 ηSUP | %
Specific power consumption in accordance with0.20 SFP | m³/h
Leakage external and internal in accordance<2% (Class A1) %
Filters according to EN 779G4 (optional on supply: F7)
Outdoor temperature without preheater install-12 to +50 tODA | °C
Spigot/duct connections160 – female Ømm
Weight (kg)39
Thermal conductivity, polystyrene insulation0,031 λ | W/mK
Heat transition figures, polystyrene insulatio<1 U | W/m²K
Insulation reaction to fire classDIN 4102-1 class B2 EN 13501 class E
Drainage hose¾ / 1 Ø/length | "/mm
Cabinet colour9016 / RAL grey galvanised metal
Voltage230 U | V
Maximum power draw with/without preheating170/1.570 P | W
Frequency50 f | Hz
Protection classIP21

The perfect setup for this job

Everything you need in one place, from functionality to safety.

For the job

UnifixSealant LK-DICHT Unifix

Seal joints and gaps against water, air and dust and fix components without screws.